Construction Details
Use the search and filter to find the construction details you're looking for. Your current filter is displayed below.
E7MCPF4 Precast Concrete Separating Floor Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Masonry Cavity, Partial fill, E7 Intermediate floor between dwelling
E5MCFF30 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor
E12MCFF4 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E12 Gable (insulation at ceiling level)
E18MCFF11 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Full fill, Party Wall, E18 P1 Party wall between
E2MCPF5 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E2 Other lintels
E5MCPF21 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Partial Fill Insulation
100mm Aircrete Block Inner Leaf (...
Appears in:
Masonry Cavity, Partial fill, E5 Ground floor
E4MCFF6 Jamb
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation...
Appears in:
Full fill, Masonry Cavity, E4 Jamb
E7MCPF5 Precast Concrete Separating Floor Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)...
Appears in:
Masonry Cavity, Partial fill, E7 Intermediate floor between dwelling
E5MCFF31 Suspended In-Situ Concrete Floor, Insulation Below Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK...
Appears in:
Full fill, Masonry Cavity, E5 Ground floor
E12MCFF5 Pitched Roof, Gable, Insulation At Ceiling Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK...
Appears in:
Full fill, Masonry Cavity, E12 Gable (insulation at ceiling level)